products
Safety Call Point – SCP
The next generation of alarm activation buttons are here.
- Feedback on press
- Remote reset
- Redundant, fail-safe design
In a critical moment, the Safety Call Point is highly visible and easy to operate, thanks to integrated illumination and large, clearly marked actuator. Instant LED and sounder confirmation reassure users that the alarm has been successfully triggered and helps guide responders.
Active monitoring continuously supervises operational status while the redundant output and buttons safeguard against failure. Remote reset capability and case tamper detection further enhance the SCP and help ensure the button will work when it matters most.
APPLICATIONS
- Duress alerts
- Lockdown activations
- Assistance requests
FEATURES
- Industry leading safety & reliability
- Visual and audible feedback when pressed
- Redundant activation switches
- Redundant relay output
- Active monitoring for power fail and cable cut/disconnect
- Case and wall removal tamper alarm
- Large tactile actuator with coloured backlit text
- Remote and local reset
- AUX output for separate alarm indicators
- Activation guard
- Adjustable volume and LED brightness
SCAR -C Dress plate used when replacing light switch style buttons.
Allows re-use of fixings and conceals holes/paint lines.
Safety
SCPs are designed to provide the most reliable method of manual alarm activation on the market. The design is inherently fail-safe with redundancy and active monitoring. Safety features include:
- Redundant activation switches
- Redundant alarm output
- Active monitoring for power fail and cable cut/disconnect.
- Case and wall removal tamper alarm
- Large, backlit, tactile actuator with feedback
- Dedicated output for separate alarm indicators
Activation switches.
The actuator presses on four individual switches. Each is rated for 100,000 operations. Each switch independently activates the SCP. All four switches would have to fail to prevent activation.
Redundant output.
A unique safety feature of the SCP is two output relays that provide redundancy. The relays are connected in such a way that if one relay fails the other relay will still provide a reliable alarm output.
Active Monitoring.
The SCP is powered and monitored by the security or access control system. A power failure or cable disconnection will result in an instant alarm transmission.
Tamper Alarm.
A tamper switch monitors the SCP for both case opening and unit removal from the wall. This helps notify the security/safety team when an SCP has been accidentally, intentionally or maliciously tampered with and helps ensure maximum uptime.
Back lighting & Feedback.
The SCP actuator & text is back lit to help users identify the SCP location and guide them to press the actuator correctly. Once pressed the back lighting colour will change to red to indicate a successful activation. The standby and activation LED backlighting can be disabled independently.
Lodestar Indicator.
An onboard output is provided that can drive up to two Jack Fuse Lodestar alarm status indicators. This direct connection reduces cabling and reliance on system programming/extra hardware to provide separate local alarm indication.